Date Prev][
Date Next][
Thread Prev][
Thread Next][
Date Index][
Thread Index]
[
List Home]
[photran] PBS-Generic-Batch target system problem
|
Hi,
in PTP 9.0 from Eclipse Mars PTP, I am using System Monitoring. I want
to signal a problem that happened already some years ago
(https://dev.eclipse.org/mhonarc/lists/ptp-dev/msg06298.html)
If I create a "Generic PBS Batch" monitor for a cluster using the PBS
scheduler, I get errors of the type
LML_da_driver.pl: check request for rms hint ...
LML_da_driver.pl: check_for rms, got hint from request ... (TORQUE)
LML_da_driver.pl: check_rms_TORQUE: found pbsnodes by which
(*****************/sysprod/pbs/default/bin/pbsnodes)
LML_da_driver.pl: check_rms_TORQUE: found qstat by which
(*****************/sysprod/pbs/default/bin/qstat)
LML_da_driver.pl: check_rms_TORQUE: PBSpro found
LML_da_driver.pl: check_rms_TORQUE: seems not to be a TORQUE system
LML_da_driver.pl: rms/TORQUE/da_check_info_LML.pl unable to locate rms
TORQUE
LML_da_driver.pl: ERROR LML_da_driver.pl: could not determine rms,
exiting ...
So the "Generic PBS Batch" believes to be TORQUE.
The workaround is:
Import a "Target Configuration from Plug-in", select Generic PBS Batch.
In Project Explorer a targetConfigurations project appears with name
"Generic PBS Batch (1).xml".
Open the xml file, change resource-manager-builder/name from "Generic
PBS Batch" to "Generic PBS Batch (1)"
Change resource-manager-builder/monitor-data/schedulerType from "TORQUE"
to "PBS"
Now in System Monitoring it is possible to create a new Monitor of type
"Generic PBS Batch (1)", which works. Note that the new type appears
only if the name is changed as described above.
Isn't it an error to have "TORQUE" in the schedulerType for a "Generic
PBS Batch" configuration, since a "Generic TORQUE Batch" already exists?
Should I file a bug?
Cheers,
Gianluca
--
Gianluca Bertaina, PhD
Dipartimento di Fisica
Via Celoria 16, 20133 Milano Italia
Ufficio A/T/S5
tel: +39 02 503 17664