Dear BJ,
I missed the definition of SUBSCRIBE. If find it a tad
misleading to use uppercase for strings that should be lowercase,
but that is neither here nor there.
Does that mean that only lowercase "subscribe" but not
"SUBSCRIBE" should be accepted, or are these string in fact case
independent?
Sincerely,
James
On 3/27/23 17:22, BJ Hargrave wrote:
Lowercase “subscribe” is correct. The spec
text should be a hyperlink to
https://docs.osgi.org/specification/osgi.cmpn/8.1.0/service.event.html#org.osgi.service.event.TopicPermission.SUBSCRIBE.
I think in many of the specs, the style has been to use
uppercase names in the spec text to make it stand out from the
surrounding text as well as to reference the constant names in
the permission classes.
--
BJ Hargrave
Senior Technical Staff Member, IBM // office: +1 386 848
1781
OSGi Fellow and OSGi Specification Project lead //
mobile: +1 386 848 3788
hargrave@xxxxxxxxxx
Dear Colleagues, It
seems to me that the published
org. osgi. service. event. TopicPermission implementation
contradicts the specification. In this class, the String
constant SUBSCRIBE is defined to be "subscribe". This is
lower case,
This
Message Is From an Untrusted
Sender
|
You
have not previously corresponded
with this sender.
|
|
|
Dear
Colleagues,
It seems to me
that the published org.osgi.service.event.TopicPermission
implementation contradicts the specification. In this
class, the String constant SUBSCRIBE is defined to be
"subscribe". This is lower case, but the specification
defined SUBSCRIBE to be uppercase and these strings are case
sensitive. Am I missing something?
Sincerely,
James
On 3/27/23 12:38, Dr. James J. Hunt
wrote:
Dear Colleagues,
Why is it necessary to validate the topic of an event each
time an event is created? Would it not be better to be able
to create a validated Topic Object and only have to validate
the topic name once? We need and event bus that is
efficient for high data throughput on embedded systems, but
do not want to use a nonstandard interface.
Sincerely,
James
_______________________________________________
osgi-technology-dev mailing list
osgi-technology-dev@xxxxxxxxxxx
To unsubscribe from this list, visit https://accounts.eclipse.org
--
Dr. James J. Hunt
CEO & Geschäftsführer
aicas GmbH
Emmy-Noether-Straße 9 ● 76131 Karlsruhe ● Germany
https://www.aicas.com
● Tel: +49 721 663968 22
USt-Id: DE216375633, Handelsregister HRB 109481, AG Mannheim
Geschäftsführer: Dr. James J. Hunt
aicas incorporated
6 Landmark Sq., Ste 400 ● Stamford, CT 06901 ● USA
https://www.aicas.com
● Tel: +1 203 435 0521
aicas America limited
4023 Kennett Pike, Ste 810 ● Wilmington, DE 19807 ● USA
https://www.aicas.com
● Tel: +1 203 435 0521