Date Prev][
Date Next][
Thread Prev][
Thread Next][
Date Index][
Thread Index]
[
List Home]
Re: [cdt-dev] Refreshing UI when using IManagedOptionValueHandler
|
But if i do this, the user has no chance to work manually with the options,
because all is based on enablements.
>> The problem is that the compiler of my toolchain needs additional
>> optimization flags when i change the optimization level:
>>
>> When optimization level 0 is set, no other flags are needed, so they
>> can be disabled. When i change to optimization level 3 for example,
>> two other flags have get enabled now and one enum flag has to get
>> changed to an other value.
>
>E.g. something like this?
>
>Optimization level (enumerated option)
> O0 (enumeratedOptionValue)
> O1 (enumeratedOptionValue)
> O2 (enumeratedOptionValue)
> O3 (enumeratedOptionValue)
>
>otherflag1 (boolean option) -> enable if O3
>otherflag2 (boolean option) -> enable if O3
>
>Other enumerated option
> flag1 (enable if O1)
> flag2 (enable if O1|O2|O3)
> flag3 (enable if O3)
>_______________________________________________
>cdt-dev mailing list
>cdt-dev@xxxxxxxxxxx
>https://dev.eclipse.org/mailman/listinfo/cdt-dev