Re: [chemclipse-dev] Switching perspectives

Yep, that's necessary to archive compatibility with 3.x editors.


Best,
Philip

Am 22.08.2016 um 15:15 schrieb Alexander Kerner:

Hi Philip,

many thanks for the hint! After adding a placeholder for the area part, it works as expected!

Side note: Do not try to pack the area part inside a part stack, you will get a strange exception ;) It seems differences between editor area and views are still present here and there to some degree ;)

Best,

Alex

~~~~~~~~~~~~~~~~~~~~~~~~
OpenChrom - the open source alternative for chromatography / mass spectrometry
Dr. Alexander Kerner » Software developer » alexander.kerner@xxxxxxxxxxxxx » http://www.openchrom.net
~~~~~~~~~~~~~~~~~~~~~~~~
On 08/22/2016 11:06 AM, Philip Wenig wrote:

Hi folks,

Alex, thanks for the screencast. I assume that the following has happened:

The ChromIdent perspective doesn't have an "area" reference, which is used by other perspectives to display the chromatograms. Hence, the chromatogram are opened in the last "Part Stack" of the opened perspective. But this part stack isn't available in other perspectives. Hence, chromatograms are not displayed. Since e4, there's no differentiation between editors and views anymore. Everything is a part.

Please try the same, open another perspective and have a look at the "Select View" wizard. The opened shall be displayed in the list.

Hence, each perspective shall include a reference to the editor area.

Best
Philip


Am 22.08.2016 8:35 vorm. schrieb Philip Wenig <philip.wenig@xxxxxxxxxxxxx>:

All right,

I'll have a look at it.

Best,
Philip


Am 21.08.2016 4:39 nachm. schrieb Alexander Kerner <alexander.kerner@xxxxxxxxxxxxx>:

Hi all nonbelievers,

here is how to reproduce the problem.

Best

Alex

~~~~~~~~~~~~~~~~~~~~~~~~
OpenChrom - the open source alternative for chromatography / mass spectrometry
Dr. Alexander Kerner » Software developer » alexander.kerner@xxxxxxxxxxxxx » http://www.openchrom.net
~~~~~~~~~~~~~~~~~~~~~~~~
On 08/19/2016 09:35 PM, Philip Wenig wrote:

Hi Matthias,

also WSD chromatograms shall be displayed in different perspectives, even under MSD. They are listed under org.eclipse.ui.editorss which is the same for all perspectives.

Please report any strange behaviour so that we can try to reproduce and fix it.

Best
Philip



_______________________________________________
chemclipse-dev mailing list
chemclipse-dev@xxxxxxxxxxx
To change your delivery options, retrieve your password, or unsubscribe from this list, visit
https://dev.eclipse.org/mailman/listinfo/chemclipse-dev





_______________________________________________
chemclipse-dev mailing list
chemclipse-dev@xxxxxxxxxxx
To change your delivery options, retrieve your password, or unsubscribe from this list, visit
https://dev.eclipse.org/mailman/listinfo/chemclipse-dev



_______________________________________________
chemclipse-dev mailing list
chemclipse-dev@xxxxxxxxxxx
To change your delivery options, retrieve your password, or unsubscribe from this list, visit
https://dev.eclipse.org/mailman/listinfo/chemclipse-dev

-- 
~~~~~~~~~~~~~~~~~~~~~~~~
OpenChrom - the open source alternative for chromatography / mass spectrometry
Dr. Philip Wenig » Founder » philip.wenig@xxxxxxxxxxxxx » http://www.openchrom.net
~~~~~~~~~~~~~~~~~~~~~~~~

Back to the top